Product Details:

  • Operating Pressure 300 psi Maximum
  • Mounting Type Pipe Mounted / Wall Hung
  • Features Sight Glass, Pressure Test Point, Compact Design, Forged Brass Body
  • Control Type Manual
  • Coating Type Corrosion Resistant Coating
  • Installation Type Inline, Vertical or Horizontal Mount
  • Fire Extinguisher Type N/A (Related to Sprinkler System Testing)
  • Click to View more
X

Test and Drain Valve UL & FM Price And Quantity

  • 1 Number, Number, Number
  • 5000.0 INR/Piece
  • 4000.00 - 12500.00 INR/Piece
  • Integrated Ball Valve with Drain Port
  • Female Threaded (NPT)
  • Forged Brass
  • Approx. 600g
  • Ball Valve
  • 0°C (32°F)
  • Individual Boxed
  • Glass Sight
  • 7/32 inch (5.6 mm)
  • Low Maintenance Design

Test and Drain Valve UL & FM Product Specifications

  • Threaded End Connection (NPT)
  • Fire Sprinkler Systems Test and Drain Valve
  • Rated for 300 psi (20.7 bar)
  • Up to 180F (82C)
  • N/A (Used for flow and pressure testing in piping rather than coverage)
  • A B and C
  • Straight (Linear)
  • N/A (Related to Sprinkler System Testing)
  • Inline, Vertical or Horizontal Mount
  • Combination Ball Valve with Test and Drain Function
  • Sight Glass, Pressure Test Point, Compact Design, Forged Brass Body
  • 300 psi Maximum
  • Pipe Mounted / Wall Hung
  • Corrosion Resistant Coating
  • Up to 36 GPM (Gallons Per Minute)
  • 1 inch (25 mm)
  • Manual
  • Integrated Ball Valve with Drain Port
  • Female Threaded (NPT)
  • Forged Brass
  • Approx. 600g
  • Ball Valve
  • 0°C (32°F)
  • Individual Boxed
  • Glass Sight
  • 7/32 inch (5.6 mm)
  • Low Maintenance Design

Test and Drain Valve UL & FM Trade Information

  • No
  • Sample costs shipping and taxes has to be paid by the buyer
  • UL listed FM approved

Product Description

The Rapidrop Model 801 Test & Drain Valve with incorporated acrylic sight glass delivers a basic function for testing of water flow through sprinkler systems. Its typical application is in multi-storey buildings where water flow alarm devices are required on each floor at each riser. It may be located inside or outside of a building, connected to a single or common drain point.

Test Drain Valve is used in plumbing systems to ensure proper operation and maintenance is the test drain valve. The low points of a piping system, such as the bottom of a vertical riser or the end of a horizontal pipe run, are where it is typically installed. Its main function is to enable the removal of water from the system for maintenance or testing. Test Drain Valve frequently has a test port that can be used to gauge system pressure or flow rates in addition to acting as a drain. This can be helpful in identifying leaks that might be affecting the plumbing systems functionality.



Reliable Fire System Testing Solution

Our UL & FM-approved test and drain valve is designed for efficient and accurate testing of fire sprinkler systems. The robust forged brass body and corrosion-resistant finish ensure long-term operation under demanding fire safety conditions. Integration of a test orifice, drain port, and glass sight inspection simplifies installation and routine testing, making it a reliable choice for professional contractors, exporters, and suppliers throughout the United Kingdom.


Versatile Installation and Maintenance

This valve accommodates both inline and wall-mounted configurations, suitable for a variety of pipe layouts. The female threaded (NPT) ends provide easy connectivity. Low-maintenance construction and the straightforward manual ball valve control support hassle-free operations, reducing labor and maintenance downtime in any fire protection setup.

FAQs of Test and Drain Valve UL & FM:


Q: How is the test and drain valve installed in a fire sprinkler system?

A: The valve is installed inline or wall-mounted on the fire sprinkler piping, using the 1-inch female NPT threaded ends to ensure a secure and leak-free connection. It can be mounted vertically or horizontally, depending on the design of your system.

Q: What is the main benefit of using a forged brass body in this valve?

A: Forged brass provides exceptional durability and corrosion resistance, ensuring reliable performance and a long service life under harsh fire protection conditions.

Q: When should the test and drain valve be used during fire sprinkler system maintenance?

A: Utilize the valve during routine flow and pressure testing, as well as when draining sections of the system for inspection or repairs. Its integrated functions make these maintenance processes efficient and compliant with fire safety regulations.

Q: Where is this valve best applied within a fire protection setup?

A: The valve is specifically designed for installation on the test and drain line of wet fire sprinkler systems, making it ideal for commercial, industrial, or institutional buildings where ongoing testing and maintenance are required.

Q: What features facilitate easy inspection and operation of this valve?

A: This valve is equipped with a glass sight inspection port, manual ball valve control, and a pressure test point, enabling straightforward flow visualization, sample collection, and testing without dismantling the piping.

Q: How does the low maintenance design benefit fire sprinkler contractors and facility managers?

A: The low-maintenance design minimizes service interruptions and reduces the need for frequent part replacements, translating to lower long-term costs and consistent fire protection system reliability.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Fire Sprinkler' category



Back to top